Homicen
Solution · Energy Monitoring System

See, control and optimize power

An industrial energy management system: real-time multi-parameter metering, load analytics, anomaly detection and rule-based alerts — deployed on-prem.

Homicen EMS turns every metering point into actionable data: multi-parameter monitoring to the IEC 61850 standard, cost and load analytics, leak and overload detection, and long-term time-series storage across many sites.

Class 0.5S
Accuracy class
IEC 61850
Industrial standard
5 years
Data retention
Multi-site
Central monitoring

Key features

Multi-parameter metering

Active/reactive/apparent power, power factor, frequency, 3-phase voltage & current, kWh.

IEC 61850 industrial standard

Integrate meters and measuring devices to industrial standards, scaling flexibly.

Load & cost analytics

Break down consumption by area, shift and device to optimize energy cost.

Anomaly & leak detection

Real-time alerts on overload, voltage sag, leakage and faults.

Rule-based alert engine

Configure custom threshold rules and alert channels to fit operations.

Multi-site dashboard & 5-year history

Monitor many sites centrally and retain time-series for up to 5 years.

System architecture

One meter, the whole plant connected

A DIN-rail meter collects data over RS-485 / Ethernet from every load, processes it with on-site AI and syncs to the cloud for remote monitoring.

One meter, the whole plant connected
Inverter / SolarStorage (BESS)Power meterTemperature · pressure sensorsElectric motorProduction machinesRS-485EthernetOn-site AI & Cloud

The energy monitoring dashboard

The real Homicen EMS interface — factory overview, device management and data export in real time.

Real-time factory overview: power, energy, power factor, frequency and voltage–current charts.
Real-time factory overview: power, energy, power factor, frequency and voltage–current charts.
Managing metering devices and the status of measurement points across sites.
Managing metering devices and the status of measurement points across sites.
Export detailed data to Excel/PDF by time window for archiving and reporting.
Export detailed data to Excel/PDF by time window for archiving and reporting.
Integrate solar and energy storage

Extension · Energy storage (BESS)

Integrate solar and energy storage

On the same platform, Homicen orchestrates solar (PV), the grid and a battery storage system (BESS) through a PCS converter and a BMS — maximizing self-consumption, cutting peak-hour cost and providing backup power.

  • Synchronize PV – grid – battery storage through a bidirectional PCS converter
  • Manage battery strings by RACK / PACK with a BMS monitoring every module
  • Charge when power is cheap, discharge at peak hours to optimize cost
  • Back up critical loads when the grid goes down

Storage system components

PV
Solar power
PCS
Power converter
BMS
Battery management
RACK
Battery rack
PACK
Battery pack
EMS
Central monitoring

Benefits

Energy management on a Plan – Do – Check – Act loop

An energy-management methodology for factories, buildings, cities and microgrids — continuous measurement, analysis and optimization.

Energy management on a Plan – Do – Check – Act loop
1

Assess and control consumption, then find optimal, cost-saving ways to operate the business.

2

Reduce the labor cost of operating, computing and monitoring plant and building energy.

3

Data is secured and stored safely, avoiding loss during manual handovers.

4

Automatically compute, analyze and report — cutting time and human error versus manual work.

Technical specifications

Measured parameters and industrial standards of the Homicen EMS.

Measured parameters

Voltage
3-phase (L-L, L-N)
Current
3-phase + neutral
Power
P, Q, S
Power factor
PF
Frequency
45–65 Hz
Energy
kWh, kVARh

Accuracy & standards

Accuracy class
Class 0.5S
Standard
IEC 61850
Error
±0.5%
Harmonics
THD
Sampling
Real-time

System & storage

Deployment
On-premise
Scale
Multi-point, multi-site
Retention
Up to 5 years
Alerts
Rule-based
Integration
MQTT / API

Real-world use cases

  • Monitor power across factories, buildings and site chains
  • Optimize power factor, cut reactive-power penalties
  • Detect overload and equipment faults early
  • Periodic consumption and emissions reporting

Take control of your power

Explore Homicen EMS or contact us for a survey and integration consultation.